Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Biotechnol Bioeng ; 119(1): 176-186, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34672363

RESUMO

Various types of hemoglobin (Hb)-based oxygen carriers (HBOCs) have been developed as red blood cell substitutes for treating blood loss when blood is not available. Among those HBOCs, glutaraldehyde polymerized Hbs have attracted significant attention due to their facile synthetic route, and ability to expand the blood volume and deliver oxygen. Hemopure®, Oxyglobin®, and PolyHeme® are the most well-known commercially developed glutaraldehyde polymerized Hbs. Unfortunately, only Oxyglobin® was approved by the FDA for veterinary use in the United States, while Hemopure® and PolyHeme® failed phase III clinical trials due to their ability to extravasate from the blood volume into the tissue space which facilitated nitric oxide scavenging and tissue deposition of iron, which elicited vasoconstriction, hypertension and oxidative tissue injury. Fortunately, conjugation of poly (ethylene glycol) (PEG) on the surface of Hb is capable of reducing the vasoactivity of Hb by creating a hydration layer surrounding the Hb molecule, which increases its hydrodynamic diameter and reduces tissue extravasation. Several commercial PEGylated Hbs (MP4®, Sanguinate®, Euro-PEG-Hb) have been developed for clinical use with a longer circulatory half-life and improved safety compared to Hb. However, all of these commercial products exhibited relatively high oxygen affinity compared to Hb, which limited their clinical use. To dually address the limitations of prior generations of polymerized and PEGylated Hbs, this current study describes the PEGylation of polymerized bovine Hb (PEG-PolybHb) in both the tense (T) and relaxed (R) quaternary state via thiol-maleimide chemistry to produce an HBOC with low or high oxygen affinity. The biophysical properties of PEG-PolybHb were measured and compared with those of commercial polymerized and PEGylated HBOCs. T-state PEG-PolybHb possessed higher hydrodynamic volume and P50 than previous generations of commercial PEGylated Hbs. Both T- and R-state PEG-PolybHb exhibited significantly lower haptoglobin binding rates than the precursor PolybHb, indicating potentially reduced clearance by CD163 + monocytes and macrophages. Thus, T-state PEG-PolybHb is expected to function as a promising HBOC due to its low oxygen affinity and enhanced stealth properties afforded by the PEG hydration shell.


Assuntos
Substitutos Sanguíneos , Filtração/métodos , Hemoglobinas , Oxigênio/metabolismo , Polietilenoglicóis , Animais , Substitutos Sanguíneos/análise , Substitutos Sanguíneos/química , Substitutos Sanguíneos/isolamento & purificação , Bovinos , Hemoglobinas/análise , Hemoglobinas/química , Hemoglobinas/isolamento & purificação , Cinética , Peso Molecular , Polietilenoglicóis/análise , Polietilenoglicóis/química , Polietilenoglicóis/isolamento & purificação , Propriedades de Superfície
2.
J Biol Chem ; 290(1): 99-117, 2015 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-25371199

RESUMO

The giant extracellular hemoglobin (erythrocruorin) from the earth worm (Lumbricus terrestris) has shown promise as a potential hemoglobin-based oxygen carrier (HBOC) in in vivo animal studies. An important beneficial characteristic of this hemoglobin (LtHb) is the large number of heme-based oxygen transport sites that helps overcome issues of osmotic stress when attempting to provide enough material for efficient oxygen delivery. A potentially important additional property is the capacity of the HBOC either to generate nitric oxide (NO) or to preserve NO bioactivity to compensate for decreased levels of NO in the circulation. The present study compares the NO-generating and NO bioactivity-preserving capability of LtHb with that of human adult hemoglobin (HbA) through several reactions including the nitrite reductase, reductive nitrosylation, and still controversial nitrite anhydrase reactions. An assignment of a heme-bound dinitrogen trioxide as the stable intermediate associated with the nitrite anhydrase reaction in both LtHb and HbA is supported based on functional and EPR spectroscopic studies. The role of the redox potential as a factor contributing to the NO-generating activity of these two proteins is evaluated. The results show that LtHb undergoes the same reactions as HbA and that the reduced efficacy for these reactions for LtHb relative to HbA is consistent with the much higher redox potential of LtHb. Evidence of functional heterogeneity in LtHb is explained in terms of the large difference in the redox potential of the isolated subunits.


Assuntos
Substitutos Sanguíneos/química , Hemoglobinas/química , Óxido Nítrico/química , Nitritos/química , Subunidades Proteicas/química , Animais , Substitutos Sanguíneos/isolamento & purificação , Hemoglobina A/química , Hemoglobina A/isolamento & purificação , Hemoglobinas/isolamento & purificação , Humanos , Cinética , Nitrito Redutases/química , Óxidos de Nitrogênio/química , Oligoquetos/química , Oxirredução , Ligação Proteica , Subunidades Proteicas/isolamento & purificação , Soluções
3.
J Extra Corpor Technol ; 46(1): 77-83, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24779123

RESUMO

The Auckland Hospital cardiothoracic unit recently removed Mannitol and Voluven from its Plasma-lyte-based cardiopulmonary bypass (CPB) priming fluid. Like with any change to practice, a comprehensive audit should be performed to identify positive or negative effects. The aim of this retrospective analysis was to investigate the effect of changing the CPB prime constituents on fluid balance and clinical outcome parameters. Clinical records were reviewed for 100 consecutive patients undergoing primary, isolated coronary artery bypass grafting (CABG), 50 patients before the prime change and 50 after. All data were collated into a central database for analysis. Mean arterial pressure while on bypass was higher in the new prime group (61.5 mmHg versus 57.5 mmHg, p = .002). There was no significant difference in hematocrit, hemoglobin, serum sodium, serum potassium, or creatinine postoperatively between groups. In regard to important outcomes such as postoperative weight and fluid balance, time on ventilation, length of stay in the intensive care unit (ICU) or hospital, and mortality, there were no significant differences. Interestingly, new prime group spent a smaller proportion of their time in the ICU on mechanical ventilation (23% versus 36%, p = .022). Mannitol and Voluven, like with all drugs, carry their own potential adverse effects. This study demonstrates that removing Mannitol and Voluven from priming fluid did not have any detrimental effect on electrolytes, fluid status, and other important outcomes in this consecutive series of patients having primary isolated CABG surgery. The risk-benefit balance combined with the obvious economic benefit clearly favors removing Mannitol and Voluven from priming fluids.


Assuntos
Remoção de Componentes Sanguíneos/estatística & dados numéricos , Substitutos Sanguíneos/isolamento & purificação , Ponte Cardiopulmonar/estatística & dados numéricos , Hemofiltração/estatística & dados numéricos , Derivados de Hidroxietil Amido/isolamento & purificação , Manitol/isolamento & purificação , Complicações Pós-Operatórias/epidemiologia , Idoso , Remoção de Componentes Sanguíneos/métodos , Ponte Cardiopulmonar/métodos , Feminino , Hemofiltração/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Nova Zelândia/epidemiologia , Duração da Cirurgia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
4.
Klin Khir ; (12): 37-9, 2013 Dec.
Artigo em Ucraniano | MEDLINE | ID: mdl-24502008

RESUMO

The preparation of deproteinized hemoderivate, obtained from the calf blood, was used in complex of treatment of the patients, suffering the ischemic forms of the diabetic foot syndrome (DFS). The impact of treatment on a partial pressure of the oxygen (TcPO2) on the foot back was studied up. In noncritical ischemia of the lower extremities tissues there were established a trustworthy increase of TcPO2 in patients as well as a positive dynamics of the wounds healing. In a critical ischemia the results are heterogenous due to presence of coexistant factors, although a stable positive effect was noted.


Assuntos
Substitutos Sanguíneos/uso terapêutico , Pé Diabético/tratamento farmacológico , Doenças Vasculares Periféricas/tratamento farmacológico , Animais , Monitorização Transcutânea dos Gases Sanguíneos , Substitutos Sanguíneos/química , Substitutos Sanguíneos/isolamento & purificação , Bovinos , Pé Diabético/diagnóstico , Pé Diabético/metabolismo , Pé Diabético/cirurgia , Pé/irrigação sanguínea , Pé/patologia , Pé/cirurgia , Humanos , Infusões Intravenosas , Pessoa de Meia-Idade , Oxigênio/metabolismo , Doenças Vasculares Periféricas/diagnóstico , Doenças Vasculares Periféricas/metabolismo , Doenças Vasculares Periféricas/cirurgia , Resultado do Tratamento , Cicatrização/efeitos dos fármacos
5.
Transfusion ; 52(8): 1729-40, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22304397

RESUMO

BACKGROUND: The hemoglobin of the earthworm Lumbricus terrestris (also known as erythrocruorin, or LtEc) is a naturally occurring high-molecular-weight protein assembly (3.6 MDa) that is extremely stable, resistant to oxidation, and transports oxygen similarly to human whole blood. Therefore, LtEc may serve as an alternative to donated human red blood cells. However, a suitable purification process must be developed to produce highly pure LtEc on a large scale that can be evaluated in an animal model to determine the safety and efficacy of LtEc. STUDY DESIGN AND METHODS: We used tangential-flow filtration (TFF), an easily scalable and affordable technique, to produce highly pure LtEc from earthworms. The purity, yield, methemoglobin level, viscosity, colloid osmotic pressure, O(2) binding equilibria, and ligand-binding kinetics of the purified LtEc were measured in vitro. The purified LtEc product was then evaluated in hamsters using a hypervolemic infusion model to establish its basic biocompatibility and detect any changes in microcirculatory and systemic variables. RESULTS: TFF was able to produce LtEc with high purity and yield (5-10 g/1000 worms). The purified LtEc product did not elicit hypertension or vasoconstriction when infused into hamsters. CONCLUSION: LtEc may be easily purified and safely transfused into hamsters in small amounts (0.5-1.5 g/dL final concentration in blood) without any noticeable side effects. Therefore, LtEc may serve as a very promising oxygen carrier for use in transfusion medicine.


Assuntos
Substitutos Sanguíneos , Filtração/métodos , Hemoglobinas , Oligoquetos/química , Choque/terapia , Animais , Arteríolas/fisiologia , Substitutos Sanguíneos/análise , Substitutos Sanguíneos/isolamento & purificação , Substitutos Sanguíneos/farmacologia , Bovinos , Cromatografia Líquida , Cricetinae , Modelos Animais de Doenças , Eletroforese em Gel de Poliacrilamida , Filtração/instrumentação , Hemoglobinas/análise , Hemoglobinas/isolamento & purificação , Hemoglobinas/farmacologia , Humanos , Masculino , Mesocricetus , Metemoglobina/análise , Metemoglobina/isolamento & purificação , Modelos Biológicos , Peso Molecular , Pressão Osmótica , Oxigênio/química , Fluxo Sanguíneo Regional/fisiologia , Choque/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Viscosidade
6.
Artif Organs ; 36(2): 202-9, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21834949

RESUMO

The hemoglobin-vesicle (HbV) is an artificial oxygen carrier encapsulating a concentrated hemoglobin solution in a phospholipid vesicle (liposome). During or after transporting oxygen, macrophages capture HbVs in the reticuloendothelial system (RES) with an approximate circulation half-life of 3 days. Animal studies show transient splenohepatomegaly after large doses, but HbVs were completely degraded, and the components were excreted in a few weeks. If a blood substitute is used for emergency use until red blood cell transfusion becomes available or for temporary use such as a priming fluid for an extracorporeal circuit, then one option would be to remove HbVs from the circulating blood without waiting a few weeks for removal by the RES. Using a mixture of beagle dog whole blood and HbV, we tested the separation of HbV using a centrifugal Fresenius cell separator and an ultrafiltration system. The cell separator system separated the layers of blood cell components from the HbV-containing plasma layer by centrifugal force, and then the HbV was removed from plasma phase by the ultrafiltration system. The HbVs (250-280 nm) are larger than plasma proteins (< 22 nm diameter) but smaller than blood cell components (> 3 µm). The size of HbVs is advantageous to be separated from the original blood components, and the separated blood components can be returned to circulation.


Assuntos
Remoção de Componentes Sanguíneos/instrumentação , Substitutos Sanguíneos/isolamento & purificação , Centrifugação/instrumentação , Ultrafiltração/instrumentação , Animais , Cães , Desenho de Equipamento
7.
Protein J ; 30(1): 27-31, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21161348

RESUMO

A new protocol is described for derivatization of hemoglobin with polyethyleneglycol (PEG) via reaction of the unmodified native hemoglobin with an activated amine-reacting polyethylene glycol derivative which, unlike protocols previously described, leads to formation of a peptide bond between hemoglobin and PEG. Dioxygen binding and peroxide reactivities of the derivatized hemoglobin are examined, and found to be within reasonable limits, with the particular observation that, unlike with a few other derivatization protocols, the dioxygen affinity is slightly lower than that of native Hb. In cell culture tests (human umbilical vein epithelial cells, HUVEC), the derivatization protocol induces no toxic effect. These results show promise towards applicability for production of hemoglobin-based blood substitutes.


Assuntos
Substitutos Sanguíneos/química , Substitutos Sanguíneos/toxicidade , Hemoglobinas/química , Animais , Substitutos Sanguíneos/isolamento & purificação , Bovinos , Linhagem Celular/efeitos dos fármacos , Linhagem Celular/metabolismo , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Hemoglobinas/isolamento & purificação , Hemoglobinas/toxicidade , Humanos , Peróxido de Hidrogênio/química , Estresse Oxidativo , Oxigênio/química , Peróxidos/química , Polietilenoglicóis/química , Polietilenoglicóis/isolamento & purificação , Polietilenoglicóis/toxicidade , Umbigo/irrigação sanguínea , Veias/citologia
8.
Artigo em Inglês | MEDLINE | ID: mdl-20205612

RESUMO

Crosslinking of ultrapure hemoglobin, crystalline catalase, and superoxide dismutase resulted in a soluble nanodimensional complex of polyhemoglobin-catalase-superoxide dismutase. A less expensive and more convenient way is to crosslink bovine stroma-free hemolysate (stroma-free hemolysate) that already contains hemoglobin, catalase, and superoxide dismutase into polyhemoglobin with catalase and superoxide dismutase activities (stroma-free polyhemolysate) [21]. The objective of the present study is to evaluate the immunological properties of this stroma-free polyhemolysate. Each of three groups of rats received weekly subcutaneous injections of one of the stroma-free polyhemolysate, stroma-free hemolysate, and saline for four weeks. One week after the four cycles of weekly immunization, serum and plasma were collected for C3a complement activation tests and Ouchterlony antibody-antigen precipitation tests, respectively. Results show that stroma-free polyhemolysate retained significant antioxidant enzyme activity. The C3a complement activation test and Ouchterlony test show that four weekly subcutaneous injections of bovine stroma-free polyhemolysate did not result in any immunological reaction in rats when tested this way.


Assuntos
Antioxidantes/administração & dosagem , Substitutos Sanguíneos/metabolismo , Catalase/administração & dosagem , Ativação do Complemento/efeitos dos fármacos , Hemoglobinas/administração & dosagem , Imunidade/efeitos dos fármacos , Superóxido Dismutase/administração & dosagem , Animais , Reações Antígeno-Anticorpo/efeitos dos fármacos , Antioxidantes/isolamento & purificação , Antioxidantes/metabolismo , Substitutos Sanguíneos/administração & dosagem , Substitutos Sanguíneos/isolamento & purificação , Catalase/isolamento & purificação , Catalase/metabolismo , Bovinos , Complemento C3/metabolismo , Hemoglobinas/imunologia , Hemoglobinas/isolamento & purificação , Hemoglobinas/metabolismo , Humanos , Imunização , Injeções Subcutâneas , Masculino , Ratos , Ratos Sprague-Dawley , Superóxido Dismutase/isolamento & purificação , Superóxido Dismutase/metabolismo
9.
Artigo em Inglês | MEDLINE | ID: mdl-19444743

RESUMO

This work reports for the first time the expression of a soluble B2 globin chain that is part of the extracellular hexagonal-bilayer haemoglobin from Arenicola marina. Two recombinant B2 globins were produced, one fused with gluthatione S-tranferase (B2-GST) and the other without a fusion tag (RecB2) and requiring a different purification procedure. We also describe a new method for the expression of globin that uses Studier's auto-induction medium together with the heme precursor delta-aminolevulinic acid. Media supplementation with the heme precursor delta-aminolevulinic acid in the culture increased heme synthesis by E. coli leading to the expression of the recombinant B2 globins in their active form. RecB2 and B2-GST were expressed with a yield of up to 105 mg/l of E. coli culture. Our approach is rapid and requires only one chromatographic purification step for B2-GST and three purification steps for RecB2. The overall results on RecB2 and B2-GST show that the recombinant globins exhibit similar properties to those of Arenicola marina native HBL-Hb with a great stability and a strong oxygen binding. The results and methodologies described in this paper are the beginning of a work aiming at reconstituting a recombinant HBL-Hb by genetic engineering in order to produce an innovative oxygen carrier for therapeutic applications.


Assuntos
Substitutos Sanguíneos/metabolismo , Escherichia coli/genética , Engenharia Genética/métodos , Globinas/biossíntese , Poliquetos , Proteínas Recombinantes de Fusão/biossíntese , Adulto , Sequência de Aminoácidos , Ácido Aminolevulínico/metabolismo , Animais , Substitutos Sanguíneos/química , Substitutos Sanguíneos/isolamento & purificação , Globinas/química , Globinas/isolamento & purificação , Globinas/metabolismo , Heme/metabolismo , Hemoglobinas/metabolismo , Humanos , Espectrometria de Massas , Dados de Sequência Molecular , Oxirredução , Proteínas Recombinantes de Fusão/química , Proteínas Recombinantes de Fusão/isolamento & purificação , Proteínas Recombinantes de Fusão/metabolismo , Solubilidade , Espectrofotometria Ultravioleta
10.
Artigo em Inglês | MEDLINE | ID: mdl-19229669

RESUMO

The Labscale tangential flow diafiltration system in conjunction with polyethersulfone Biomax filters (both purchased from Millipore Inc.) were used in the following studies: (1) A crucial step in the preparation of polyhemoglobin (polyHb) is the removal of tetrameric hemoglobin (Hb), which can cause adverse side-effects. The efficiency for this depends on the integrity of the 100kDa filters. Those with lower integrity were not effective whereas those with a higher integrity of 0.075ml/min were more effective. A filter with an integrity of 0.075ml/min can reduce the initial 11.2% tetrameric Hb concentration to 1.3% using a flow rate of 0.2ml/min. Higher flow rate of 2.2ml/min was not as effective. (2) Filtration with a 100kDa filter was quick and efficient in separating stroma-free hemoglobin solutions from cellular debris from hemolysate. (3) Both 5kDa and 100kDa filters are efficient in concentrating hemoglobin solutions.


Assuntos
Filtração/métodos , Hemoglobinas/isolamento & purificação , Polímeros/metabolismo , Sulfonas/metabolismo , Substitutos Sanguíneos/química , Substitutos Sanguíneos/isolamento & purificação , Substitutos Sanguíneos/metabolismo , Filtração/instrumentação , Hemoglobinas/química , Hemoglobinas/metabolismo , Humanos , Polímeros/química , Multimerização Proteica , Pesquisa/instrumentação , Projetos de Pesquisa , Sulfonas/química
11.
Rev. bras. eng. biomed ; 19(1): 39-49, abr. 2003. tab, graf
Artigo em Português | LILACS | ID: lil-410541

RESUMO

A hemoglobina humana (Hb)vem sendo usada como ponto de partida para o desenvolvimento de substitutos para o sangue. Antes de ser submetida a reações de modificação química, a Hb precisa ser obtida com alto grau de pureza. Neste trabalho, concentrados de hemácias foram tratados por métodos convencionais para a obtenção de amostras de Hb, sob a forma de carbonil-hemoglobina (HbCO). A técnica de cromatografia de troca iônica foi usada com o objetivo de verificar-se a eficiência de resinas aniônicas na eliminação de fosfolipídeos da parede celular, ainda residuais nas soluções de HbCO. Experimentos foram realizados com duas resinas de troca aniônica, uma fraca e outra forte. Os extratos orgânicos da solução de purificada adicionalmente por meio de cromatografia em resina de troca aniônica forte, AG MP-1, foram analisados por cromatografia líquida de alta pressão (HPLC). Os resultados mostraram que a resina AG MP-1, sob as condições utilizadas, foi capaz de reter grande parte do total de fosfolipídeos pesquisados


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia por Troca Iônica/métodos , Fosfolipídeos/isolamento & purificação , Substitutos Sanguíneos/isolamento & purificação , Substitutos Sanguíneos/síntese química , Hemoglobina A
12.
J Biotechnol ; 100(3): 267-75, 2003 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-12443858

RESUMO

A solid phase adsorption method was proposed to prepare well-defined bovine serum albumin-bovine hemoglobin (Hb) conjugate. After adsorption by the solid phase, Q Sepharose Fast Flow media, bovine serum albumin (BSA) molecules were allowed to react with glutaraldehyde. The spacing out of BSA molecules on the solid phase was assumed to limit polymerization of BSA molecules, except some molecules bound closely on the solid phase resulting in minor dimer formation. Following the elution procedure, the activated monomeric BSA was separated from the dimers by gel filtration chromatography on Superdex 200 and then reacted with bovine Hb at 4 degrees C and pH 9.5. The 1:1 (BSA:Hb) conjugate was obtained with the yield of 64%. The P(50) values of the conjugates, prepared under anaerobic and aerobic conditions, were 19.1 and 14.2 mmHg, respectively. The dependence of the P(50) on chloride ions for the conjugate was slightly diminished, presumably due to covalent attachment of BSA to bovine Hb.


Assuntos
Cromatografia em Agarose/métodos , Glutaral/química , Hemoglobinas/síntese química , Sefarose/química , Soroalbumina Bovina/síntese química , Adsorção , Substitutos Sanguíneos/síntese química , Substitutos Sanguíneos/isolamento & purificação , Cloro/química , Hemoglobinas/isolamento & purificação , Concentração de Íons de Hidrogênio , Substâncias Macromoleculares , Oxigênio/química , Ligação Proteica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soroalbumina Bovina/isolamento & purificação
14.
Eur J Med Res ; 5(5): 209-16, 2000 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-10806123

RESUMO

Perfluorocarbons (PFCs) combine rather unique chemical and physical properties together with physiological inertness. Due to this, they have become useful tools in medicine. Whereas the majority of applications benefit from their excellent oxygen solubility, there are several applications making use of other PFC properties. The great importance of PFC ultra-purity is especially emphasized.


Assuntos
Substitutos Sanguíneos , Fluorocarbonos , Animais , Substitutos Sanguíneos/síntese química , Substitutos Sanguíneos/isolamento & purificação , Cromatografia Gasosa , Fluorocarbonos/síntese química , Fluorocarbonos/isolamento & purificação , Humanos , Modelos Químicos
15.
J Lab Clin Med ; 132(4): 313-9, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-9794703

RESUMO

To better understand the vascular activity of hemoglobin-based (Hb-based) oxygen carriers, the endothelial permeability characteristics of Hb derivatives having various molecular masses were defined by using monolayers of bovine endothelial cells cultured on microporous membranes. The endothelial permeability of unmodified bovine Hb was almost twice that of bovine serum albumin. Intramolecularly cross-linked human Hb showed slightly but significantly reduced permeability as compared with unmodified bovine Hb. Polyethyleneglycol modification or haptoglobin binding to Hb further reduced the permeability. These properties were intensified in conditions in which the endothelial barrier function was reduced by pretreatment with either interleukin-6 (100 ng/mL, 21 hours) or lipopolysaccharide (1 microg/mL, 10 hours). In contrast, there was little permeability of liposome-encapsulated Hb, and it was almost unaffected by the pretreatments. These data provide the first information that Hb derivatives with smaller molecular masses show larger transendothelial flux. Because Hb is a potent scavenger of endothelium-derived relaxing factor (EDRF), our observations support the idea that smaller Hb-based acellular oxygen carriers are potent vasoconstrictors as a result of abluminal EDRF scavenging.


Assuntos
Endotélio Vascular/metabolismo , Hemoglobinas/metabolismo , Animais , Arginina/farmacologia , Substitutos Sanguíneos/isolamento & purificação , Substitutos Sanguíneos/metabolismo , Bovinos , Células Cultivadas , Relação Dose-Resposta a Droga , Portadores de Fármacos , Endotélio Vascular/citologia , Escherichia coli , Humanos , Interleucina-6/farmacologia , L-Lactato Desidrogenase/metabolismo , Lipopolissacarídeos/farmacologia , Lipossomos , NG-Nitroarginina Metil Éster/farmacologia , Óxido Nítrico/metabolismo , Permeabilidade , Soroalbumina Bovina/metabolismo
20.
Adv Exp Med Biol ; 345: 205-13, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-8079709

RESUMO

The production of hyperpolymer haemoglobins, exhibiting sufficiently low colloid osmotic pressure and sufficiently low viscosity is possible, even in concentrations, and therewith oxygen transport capacity, high enough to supply an organism adequately with oxygen. Such hyperpolymers, when infused, are tolerated by anaesthetized rats in acute blood exchange experiments. Ex vivo determinations of plasma colloid osmotic pressure and both, plasma and whole blood kinematic viscosity during blood exchange showed, that corresponding properties found in vivo were refound within the animal. Furthermore we could show that hyperpolymers produced from desoxygenated human haemoglobin with divinyl sulfone as a crosslinker take part in tissue supply of oxygen to a substantial degree (about 50%) without and with increased inspiratory oxygen fraction, demonstrating the principal ability of hyperpolymers to transport oxygen in blood and to deliver it to tissues.


Assuntos
Substitutos Sanguíneos/farmacologia , Hemoglobinas/farmacologia , Animais , Transporte Biológico Ativo , Substitutos Sanguíneos/isolamento & purificação , Substitutos Sanguíneos/metabolismo , Viscosidade Sanguínea , Reagentes de Ligações Cruzadas , Hemoglobinas/isolamento & purificação , Hemoglobinas/metabolismo , Humanos , Masculino , Pressão Osmótica , Oxigênio/sangue , Oxigênio/metabolismo , Ratos , Ratos Sprague-Dawley , Sulfonas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...